-
GDP-311MIX SF6/N2 Mixed Gas Purity Analyzer
The GDP-311MIX SF6/N2 mixed gas purity analyzer integrates SF6 purity testing and O2 testing. With one on-site measurement, all indicators can be tested, greatly saving gas in the equipment, reducing user workload, and improving work efficiency.
The GDP-311MIX SF6/N2 mixed gas purity analyzer adopts the best sensors; The purity of SF6 gas adopts a stable and reliable German Smart Gas NDIR principle sensor, and oxygen testing uses a British CITY electrochemical sensor. Color LCD display, real-time display of various parameters, foolproof operation throughout the process, built-in rechargeable battery, dual-use for AC and DC.
-
GDLD-313IR SF6 Gas Leak Detector
GDLD-313IR SF6 Gas Leak Detector is updated model, which is infrared red type leak detector (NDIR technology). It is LCD display and real-time shows SF6 concentration. It rapidly detects SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It’s a good device suitable for power supply department, installation and overhaul unit, power test institute.
The smart quick intelligent test system is used, the software registering number 1010215, trademark registering number 14684781.
-
GDP-311CAW 3-in-1 SF6 Quality Analyzer
GDP-311PCAW SF6 gas quality analyzer is a portable device designed to measure SF6 gas purity, dew point, composition, CF4 content and air content.
-
GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device
GDQC-16A Gas Vacuum Pumping and Filling Device is mainly used as auxiliary equipment of gas equipment GCBT, GIS, SF6 during installing, debugging and repairing in various power supply companies, power transmission engineering companies, power plants, ultra high voltage transmission, SF6 gas electrical switch manufacturing plant and other departments.
-
GDQH-601-50 SF6 Gas Recycling Machine
The model GDQH-601-50 is special machine of vacuumizing and filling device. It is suitable for SF6 electrical equipment, GIS manufacturer and research institute.
-
GDQH-31H Portable SF6 Gas Recovery Device
GDQH-31W Portable SF6 Gas Recovery Device (MINI) is used in the manufacturing plant of SF6 gas insulated electrical equipment and operation & scientific research departments to fill electrical equipment with SF6 gas and recover SF6 gas from electrical appliances used or tested.
At the same time, it is purified and compressed and stored in the storage tank. Suitable for ring network distribution network below 50kV.
-
GDQH-31W Portable SF6 Gas Recovery Device
GDQH-31W Portable SF6 Gas Recovery Device (MINI) is used in the manufacturing plant of SF6 gas insulated electrical equipment and operation & scientific research departments to fill electrical equipment with SF6 gas and recover SF6 gas from electrical appliances used or tested.
At the same time, it is purified and compressed and stored in the storage tank. Suitable for ring network distribution network below 50kV.
-
GDWG-IV SF6 Gas Leak Detector(IR Series)
GDWG-IV SF6 Gas Leak Detector is infrared red type leak detector(NDIR technology). It is color OLED display and real-time shows SF6 concentration.
-
GDWG-V SF6 Gas Leak Detector (IR type, Double display)
GDWG-V SF6 Gas Leak Detector is infrared red type leak detector (NDIR technology) with double display. It is color INCELL TFT display and real-time shows SF6 concentration.
-
GDPDS-341 SF6 Electrical Insulation State Comprehensive Analyzer
At present, the UHV voltage level of 110KV and above uses SF6 gas-insulated enclosed GIS as the main primary equipment of the substation, the evaluation of GIS internal insulation status is mainly achieved by partial discharge detection method and SF6 gas chemical analysis method at home and abroad.
-
GDSF-411CPD SF6 Gas Comprehensive Analyzer
GDSF-411CPD SF6 gas comprehensive analyzer is a portable device designed to measure SF6 gas dew point, purity and decomposition product.
-
GDSF-311WPD 3-In-1 SF6 Gas Analyzer
GDSF-311WPD (GDSF-411WPD) is an ideal instrument when it is necessary to test water content, purity and decomposition products of SF6 gas. The core component of dew point test is DRYCAP® series sensors produced by Finland Vaisala company.